Filter Results By:

Products

Applications

Manufacturers

Showing results: 421 - 435 of 458 items found.

  • NI-9229, ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module

    780180-01 - NI

    ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module - The NI‑9229 performs differential analog input. The NI‑9229 is an effective general-purpose analog module because of its resolution, sample rate, and input range. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating.

  • NI-9229, ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module

    779785-01 - NI

    ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module - The NI‑9229 performs differential analog input. The NI‑9229 is an effective general-purpose analog module because of its resolution, sample rate, and input range. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating.

  • NI-9229, ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module

    779785-02 - NI

    ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Module - The NI‑9229 performs differential analog input. The NI‑9229 is an effective general-purpose analog module because of its resolution, sample rate, and input range. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating.

  • NI-9224, ±10 V, 1 kS/s/ch, 24-Bit, Simultaneous Input, 8-Channel C Series Voltage Input Module

    783862-01 - NI

    ±10 V, 1 kS/s/ch, 24-Bit, Simultaneous Input, 8-Channel C Series Voltage Input Module - The NI‑9224 performs differential analog input. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. The NI‑9224 is simultaneous sampling with two options for filtering a low-latency filter or a 50/60 Hz rejection filter. The low-latency filter enables users to use this module in industrial or control applications while getting better external noise rejection.

  • Mechanical Creep and Rupture Testing Machine

    MRC Series - Jinan Testing Equipment IE Corporation

    MRC series mechanical creep and rupture testing machine with single-lever structure is designed for long-term creep and stress rupture test applications. The series mechanical creep and rupture testing system is mainly for the metallic materials under room or elevated temperature according to GB/T2039, GB/T 20120, EN ISO 204-2009 and ASTM E139. The creep and rupture testing machine can also maintain constant loads for extended periods of time. Through the mechanical advantage of the lever arm loading system, constant loads can be maintained with a high degree of accuracy for long duration. This creep and rupture tester uses dead weights without continuous operation and the dependency of a mechanically powered drive. The creep and rupture testing system is an ideal equipment for metallurgy manufacturer, research institute, colleges and other relevant factories and mines.

  • Multiple Output Bidirectional PSU

    LAB-MOBI - Electronic Test & Power Systems

    The LAB-MOBI is a series of multi channel High Power Bidirectional PSUs. Each system is able to operate as either a DC Source or a DC Electronic Load. This integrated approach features high dynamics enabling the user to switch seamlessly between quadrants. When sinking energy from the unit under test the LAB-MOBI automatically inverts the DC to AC and synchronises this output to the grid. Dedicated application modes are available for battery cycling and emulation, which can be used to implement specific test routines. Other common applications the LAB-MOBI is used for include testing electric motors, fuel cells, super capacitors and solar panels. Max. Volt. Output 1000V,Min. Power 60kW, Max. Power 500kW.

  • Protocol Analyzer

    PGY-SSMlite SD - Prodigy Technovations Pvt. Ltd.

    PGY-SSMlite SD Protocol Analyzer is the most feature rich comprehensive Protocol Analyzer available to capture and debug SD protocol data. PGY-SSMlite Protocol Analyzer supports SD, Protocol analysis for wide data rate up to 200MHz SDR mode (UHS-I). The innovative active probe has minimum electrical loading on device under test (DUT) and allows the protocol data capture without affecting the performance DUT. PGY-SSMlite protocol analyzer allows industry first continuous streaming of protocol data from PGY-SSMlite Protocol Analyzer to host system (using USB3.0 or GbE interface). Comprehensive decoding of data, protocol tests, and error analysis enables verification of communication of SD host and device.

  • Hydraulics Testing

    National Technical Systems

    Fluid power systems play a critical role in many industries, and are one of the three major forms of power transmission along with electrical and mechanical power systems. In many cases, however, mechanical and electrical methods cannot provide a practical power transmission solution. In these cases, fluid power (whether hydraulic or pneumatic) is often used because it can deliver linear and rotary motion with high force and torque within a smaller, lighter package than is possible with other forms of power transmission. Some of the most common applications of hydraulic systems are in heavy construction and off-highway equipment. Other applications can be seen in aircraft, mass transportation systems (such as trains), construction, mining, agriculture, waste reduction, and utility equipment. The various components (such as valves, actuators, cylinders, accumulators, etc.) that make up these systems must perform reliably and have a reasonable life span. Only a thorough test program carried out under simulated field use conditions can insure that any component part or assembly will meet its original design goals for performance, reliability and longevity. Many internationally recognized organizations have published test standards that apply to hydraulic/pneumatic and fluid power systems and components. Some of these organizations are:

  • NI-9239 , ±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module

    780181-01 - NI

    ±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9239 performs differential analog input. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating. Designed for both speed and accuracy, the NI‑9239 is an effective general-purpose analog module because of its resolution, sample rate, and input range.

  • NI-9239, ±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module

    779593-01 - NI

    ±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9239 performs differential analog input. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating. Designed for both speed and accuracy, the NI‑9239 is an effective general-purpose analog module because of its resolution, sample rate, and input range.

  • NI-9239 , ±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module

    782402-01 - NI

    ±10 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9239 performs differential analog input. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating. Designed for both speed and accuracy, the NI‑9239 is an effective general-purpose analog module because of its resolution, sample rate, and input range.

  • sbRIO-9229 , Non-Enclosed, ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module

    780874-01 - NI

    Non-Enclosed, ±60 V, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The sbRIO‑9229 performs differential analog input. The sbRIO‑9229 is an effective general-purpose analog module because of its resolution, sample rate, and input range. With channel‑to‑channel isolation, your entire system, including the device under test, is protected from harmful voltage spikes up to the isolation rating. In addition to safety, isolation eliminates measurement errors caused by ground loops because the front end of the module is floating. Non-enclosed modules are designed for OEM applications.

  • Common Metallic Pendulum Impact Testing Machine

    JB-(C/D) - Jinan Testing Equipment IE Corporation

    KB- (C/D) common type metallic pendulum impact testing system is the basic model for impact tester. The metallic pendulum impact tester is used to determine the impact resistance of metal materials under dynamic load and capable of doing a large number of impact tests continuously. The display method for the models is different, respectively there are analog dial display, touch screen digital display and computer display. For the later two models, it can display the impact power, impact toughness, and pendulum rotation angle. All the testing reports can be printed out. The metallic pendulum impact testing system is the essential quality control equipment for metal material manufacturers and QC departments, as well as the necessary instrument of research institutes for new material research.

  • LED Driver Automatic Test System

    ATE-2 - Lisun Electronics Inc.

    •This system includes 2 groups (left and right); the 2 groups can work in turn, so that to improve the work efficiency. For example, if the left is on working, then the right can make wire connection. •It can test 4 LED drivers input and output at one time. •The equipment can connect with electronic load and LED load, the two difference loads can be fast switch under the control of computer. •Enable to print out the series number and parameters of sub-quality products by working with a micro-printer, •Enable to achieve the bar-code record function by working with a bar-code scanner. •The test report can be saved as Excel file for consult, statistic and analysis purpose. •Good software interface to freely choose the difference parameters combination, so that to meet different demands. All the parameters can set limit, and with the quality analysis function.

  • PXI 5A Fault Insertion Switch 5-Channel

    40-196-101 - Pickering Interfaces Ltd.

    The 40-196 is a 10 Channel 5A Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Shorting relays on each channel enable UUT signals to be subjected to external user applied fault conditions or to be shorted to the adjacent signal in the same channel. Relays in line with the signal allow open circuit conditions to be simulated on either side or both sides of a channel signal pair. The switching topology of the 40-196 allows channels to be interconnected so that complex fault insertion systems can be constructed.

Get Help